MATERIAL  SAFETY  DATA  SHEET          

I  Product:   AQUA  LUBE  300      

Description:  Viscous Liquid.                                                                   

Manufacturer:  BIG STATE PUMP CO.            Emergency Telephone No.             Date Prepared: September 2003.

c/o Chemical Solutions Int’l. Corp.                   (832) 736-9345

          P.O. Box 891185                                      (800) 424-4804

   Houston, TX 77289-1185                   E-mail:jimarnold@chemicalsolutionsintl.com

                                                             Home Page:www.chemicalsolutionsintl.com

II  Health Hazard Data:                                

                                                                         VII    Hazardous  Ingredients: 

Permissable Concentrations (Air): If used in                 

applications where mist may be generated,                    Formula: A mixture of liquid hydrocarbons refined from petroleum.

observe a TWA/PEL of 5mg/m³ for mineral oil             Chemical Name: White mineral oil, USP.   Toxic & Hazardous 

mist (OSHA and ACGIH).                                              Ingredients: None.  This product is a fully refined while mineral oil 

Chronic Effects of Overexposure: No Data Available.   meeting the requirements of the United States Pharmacopeia XXII                     

Emergency & First Aid:  Skin:Wash with water &         and the requirements of the FDA as per 21 CFR 172.878.

soap. Eyes: Flush with large amounts of water for at      ments of the FDA as per 21 CFR 172.878.  This product is made in a

least 15 minutes.  Inhalation: Not applicable.                  manner to insure quality, purity and stability. Handle carefull to           

If Swallowed: Contact a physician immediately.             preserve its original quality. May contain up to 10ppm Tocopherols   

                                                                                         as stabilizer. Hazard warning label not required under OSHA Hazard

III   Handling of Spills, Leaks, Storage:       communication standard 29 CFR 1910.1200.

 

 For Clean-up and Dispose:  Shut off leak and dike up   VIII Fire and Explosion Data:

large spills. Absorb with an inert material such as earth,

sand or vermiculite. Sweep up and dispose of in               Special Fire Fighting Procedures: Wear self-contained breathing

accordance with Federal, State and local regulations.       apparatus. Water spray is an unsuitable extinguishing agent.

Storage: Keep away from heat and flames. Do not            Unusual Fire & Explosion Hazards: None

store near strong oxidizing agents.                                     Flashpoint: (Method used-ASTM D-92)  >  188º C (370º F) 

Maximum Storage Temperature: 66º C (150º F)                Flammability Limits % : No Data Available    

                                                                                            Extinguishing Agents: Dry chemical or waterfog or CO2 , foam                     

IV  Physical Data:                                                       or sand/earth.  Closed containers exposed to fire may be cooled                               

                                                                                             with water.

Appearance & odor: Clear & viscous liquid, odorless.                                                     

Specific Gravity (Water=1)..............<1 at 15º C                  IX  Special Protection & Precautions:

Boiling Point...................................>230° C (450º F)                                           

Evaporation Rate ............................ 0 at 25º C                    Ventilation Type Required (Local, Mechanical, Special): 

Solubility in water (By weight %):Negligible at 25º C        Local if necessary to mantain allowable PEL (Permissible 

Melting Point.....................................N/A                             exposure limit) or TLV(Threhold limit value).

Vapor  Pressure.............. (MM Hg at 20º C) .....< 0.05        Respiratory Protection (Specify Type) : None                                

Vapor Density.....(Air=1)....................Not Applicable         Protective Gloves: None. Eye Protection: Chemical safety goggles.    

pH (as is):...........................................Not Applicable.         Other Protective Equipment: None

Viscosity SSU at 100º F: ..................>100

Volatile (By weight %): ....................0 at 25º C                 ATTENTION: Never use pressure to empty; drum is not a 

                                                                                             pressure vessel. When empty, drum may have vapor or product 

V   Reactivity  Data:                                           residue. Residual vapors may explode on ignition do not puncture, drill,    

                                                                                              grind, or weld on or near this container.

Stability: Product is stable under normal conditions.           NJ/PA R-T-K INFO: White Mineral Oil CAS # 8042-47-5

Incompatibility: Keep away from strong oxidizers such

as hydrogen peroxide, bromine, and chromic acid.              *We believe the statements, technical information and recommendations

Hazardous Decomposition Products: Carbon monoxide     contained herein are reliable, but they are reliable, but they are given 

and  carbon dioxide from burning.                                        without warranty or guarantee of any kind, express or implied, and we

                                                                                                         assume no responsability for any loss, damage, or expense, direct or                        

VI   Transportation Data:                                             consequential, arising out of their use.      

 

D.O.T.: Not Regulated.

Reportable Quantity: Not Applicable

Freight Classification: 65 Petroleum Oil, N.O.I.B.N.   Special Transportation Notes: NONE


"To the best of our knowledge the information contained in this MSDS is accurate. However, neither Chemical Solutions Int'l. Corp.
nor any of its affiliates makes any warranty expressed or implied, or accepts any liability in connection with this information or its use."